{"id":4157,"date":"2020-05-20T09:04:50","date_gmt":"2020-05-20T08:04:50","guid":{"rendered":"https:\/\/www.operationalgroup.com\/?page_id=4157"},"modified":"2024-03-05T15:45:05","modified_gmt":"2024-03-05T15:45:05","slug":"exsis-produkt-information","status":"publish","type":"page","link":"https:\/\/www.operationalgroup.com\/de\/optimisation\/exsis-produkt-information\/","title":{"rendered":"ExSis Produkt Information"},"content":{"rendered":"<h3 class=\"p1\">Das ExSis Gaswarnsystem von Operational zur \u00dcberwachung von brennbaren Gasen mit katalytischen oder Infrarot- Sensoren bietet in umfassender Weise eine Komplett-L\u00f6sung fu\u0308r die sicherheitstechnischen Anforderungen im Bereich der industriellen Umwelttechnik.<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-4214 size-medium\" src=\"https:\/\/www.operationalgroup.com\/wp-content\/uploads\/2019\/05\/ExSisCut450px-281x300.png\" alt=\"ExSis machine\" width=\"281\" height=\"300\" srcset=\"https:\/\/www.operationalgroup.com\/wp-content\/uploads\/2019\/05\/ExSisCut450px-281x300.png 281w, https:\/\/www.operationalgroup.com\/wp-content\/uploads\/2019\/05\/ExSisCut450px.png 450w\" sizes=\"auto, (max-width: 281px) 100vw, 281px\" \/><\/p>\n<ul>\n<li class=\"p1\">Operational entwirft, liefert, installiert und wartet Gaswarnsysteme zur \u00dcberwachung von L\u00f6sungsmitteln in \u00dcbereinstimmung mit den Anforderungen der EN 1539, EN 60079-21-1 und EN 13849-1.<\/li>\n<li class=\"p1\">Unsere Systeme sind modular aufgebaut, kompakt und k\u00f6nnen in jede Art von Kanal, Ofen oder Trockner integriert werden.<\/li>\n<\/ul>\n<h3 class=\"p1\">Vorteile des ExSis-Systems:<\/h3>\n<ul>\n<li class=\"p1\">Erfu\u0308llt den Sicherheitsstandard PL-d nach EN 1539:2015 bei Anschluss an geeignete Alarmund Stopp-Kreise.<\/li>\n<li class=\"p1\">ExSis Sicherheits System wurde von unabh\u00e4ngiger Seite fu\u0308r den Einbau in PL-d Sicherheitskreise zertifiziert.<\/li>\n<li class=\"p1\">Schnell reagierender IR Sensor.<\/li>\n<li class=\"p1\">Werksseitige IR-Kalibration.<\/li>\n<li class=\"p1\">Geschu\u0308tzte Probeentnahmeleitung zur Vermeidung von Besch\u00e4digungen.<\/li>\n<li class=\"p1\">Geschlossenes, abschlie\u00dfbares Geh\u00e4use.<\/li>\n<li class=\"p1\">Erm\u00f6glicht Energieeinsparung im Trocknungsprozess.<\/li>\n<li class=\"p1\">Erm\u00f6glicht verringertes Abluftvolumen zur Abluftreinigung, gleich bedeutend mit kleinerer Anlagentechnik und geringerem Invest.<\/li>\n<li class=\"p1\">Erm\u00f6glicht gu\u0308nstigere Produktionskosten durch geringeres Abluftvolumen und h\u00f6here L\u00f6sungsmittelkonzentrationen.<\/li>\n<\/ul>\n<h3 class=\"p1\">Unsere Produkte<\/h3>\n<p class=\"p2\"><strong>ExSis<\/strong> &#8211; Die Grundversion ist ein Einzel-Sicherheitssystem fu\u0308r Gasentnahme und -u\u0308berwachung mit prozentualer Anzeige der UEGKonzentration. Komplett mit Display und integrierten Alarmen, das Design ist kompakt und wartungsfreundlich.<\/p>\n<p class=\"p2\"><strong>ExSis Multi<\/strong> &#8211; Dieses Steuerungssystem mit mehreren Bedienfeldern ist der perfekte Ersatz fu\u0308r ein herk\u00f6mmliches Racksystem. Es erm\u00f6glichtdie Integration der UEG Gasu\u0308berwachung in bestehende Steuerungsprozesse bei gleichzeitiger Optimierung von Effizienz und Sicherheit.<\/p>\n<h3 class=\"p1\">Sensor Optionen<\/h3>\n<p class=\"p1\"><strong>IR \u2013 Infrarot<\/strong> &#8211; Der Infrarotsensor arbeitet nach dem Prinzip der Lasertechnologie zur \u00dcberwachung der Gasreaktionszeiten. Er zeichnet sich durch kurze Reaktionszeiten und Wartungsfreundlichkeit aus. Kohlenstoffatome im Gas \u00e4ndern die Reaktionszeit, die mit einem einstellbaren Referenzpunkt verglichen wird, um so den Gasgehalt zu bestimmen.<\/p>\n<p class=\"p1\"><strong>CAT \u2013 Catalytic<\/strong> &#8211; der katalytische Sensor arbeitet nach dem Prinzip der W\u00e4rmet\u00f6nung. Das Gas wird u\u0308ber einen beheizten Pellistor mit Katalysatormaterial gefu\u0308hrt, ein zweiter Pellistor ohne Katalysatormaterial dient als Referenzquelle. Anhand der Abweichung der elektrischen Widerst\u00e4nde wird der Gasgehalt bestimmt.<\/p>\n<p><a href=\"https:\/\/www.operationalgroup.com\/wp-content\/uploads\/2024\/03\/Operational-ExSis-IR-CAT-TUV-Certification-2024-to-2028.pdf\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-10930 size-medium\" src=\"https:\/\/www.operationalgroup.com\/wp-content\/uploads\/2024\/03\/Operational-ExSis-IR-CAT-TUV-Certification-2024-to-2028thumbnail-212x300.jpg\" alt=\"\" width=\"212\" height=\"300\" srcset=\"https:\/\/www.operationalgroup.com\/wp-content\/uploads\/2024\/03\/Operational-ExSis-IR-CAT-TUV-Certification-2024-to-2028thumbnail-212x300.jpg 212w, https:\/\/www.operationalgroup.com\/wp-content\/uploads\/2024\/03\/Operational-ExSis-IR-CAT-TUV-Certification-2024-to-2028thumbnail.jpg 595w\" sizes=\"auto, (max-width: 212px) 100vw, 212px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n\n\t\t<style>\n\t\t\t#gallery-1 {\n\t\t\t\tmargin: auto;\n\t\t\t}\n\t\t\t#gallery-1 .gallery-item {\n\t\t\t\tfloat: left;\n\t\t\t\tmargin-top: 10px;\n\t\t\t\ttext-align: center;\n\t\t\t\twidth: 50%;\n\t\t\t}\n\t\t\t#gallery-1 img {\n\t\t\t\tborder: 2px solid #cfcfcf;\n\t\t\t}\n\t\t\t#gallery-1 .gallery-caption {\n\t\t\t\tmargin-left: 0;\n\t\t\t}\n\t\t\t\/* see gallery_shortcode() in wp-includes\/media.php *\/\n\t\t<\/style>\n\t\t<div id='gallery-1' class='gallery galleryid-4157 gallery-columns-2 gallery-size-medium'><dl class='gallery-item'>\n\t\t\t<dt class='gallery-icon landscape'>\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"169\" src=\"https:\/\/www.operationalgroup.com\/wp-content\/uploads\/2021\/09\/ExSis800px_1-300x169.jpg\" class=\"attachment-medium size-medium\" alt=\"ExSIS\" aria-describedby=\"gallery-1-6606\" srcset=\"https:\/\/www.operationalgroup.com\/wp-content\/uploads\/2021\/09\/ExSis800px_1-300x169.jpg 300w, https:\/\/www.operationalgroup.com\/wp-content\/uploads\/2021\/09\/ExSis800px_1-768x432.jpg 768w, https:\/\/www.operationalgroup.com\/wp-content\/uploads\/2021\/09\/ExSis800px_1.jpg 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/>\n\t\t\t<\/dt>\n\t\t\t\t<dd class='wp-caption-text gallery-caption' id='gallery-1-6606'>\n\t\t\t\tExSIS LEL gas monitoring system\n\t\t\t\t<\/dd><\/dl><dl class='gallery-item'>\n\t\t\t<dt class='gallery-icon landscape'>\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"169\" src=\"https:\/\/www.operationalgroup.com\/wp-content\/uploads\/2021\/09\/ExSis800px_2-300x169.jpg\" class=\"attachment-medium size-medium\" alt=\"LEL gas monitoring system\" aria-describedby=\"gallery-1-6611\" srcset=\"https:\/\/www.operationalgroup.com\/wp-content\/uploads\/2021\/09\/ExSis800px_2-300x169.jpg 300w, https:\/\/www.operationalgroup.com\/wp-content\/uploads\/2021\/09\/ExSis800px_2-768x432.jpg 768w, https:\/\/www.operationalgroup.com\/wp-content\/uploads\/2021\/09\/ExSis800px_2.jpg 800w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/>\n\t\t\t<\/dt>\n\t\t\t\t<dd class='wp-caption-text gallery-caption' id='gallery-1-6611'>\n\t\t\t\tLEL gas monitoring system \n\t\t\t\t<\/dd><\/dl><br style=\"clear: both\" \/>\n\t\t<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>Das ExSis Gaswarnsystem von Operational zur \u00dcberwachung von brennbaren Gasen mit katalytischen oder Infrarot- Sensoren bietet in umfassender Weise eine&#8230;<\/p>\n","protected":false},"author":24,"featured_media":3683,"parent":6225,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-solutions-child.php","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"footnotes":""},"class_list":["post-4157","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.operationalgroup.com\/de\/wp-json\/wp\/v2\/pages\/4157","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.operationalgroup.com\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.operationalgroup.com\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.operationalgroup.com\/de\/wp-json\/wp\/v2\/users\/24"}],"replies":[{"embeddable":true,"href":"https:\/\/www.operationalgroup.com\/de\/wp-json\/wp\/v2\/comments?post=4157"}],"version-history":[{"count":7,"href":"https:\/\/www.operationalgroup.com\/de\/wp-json\/wp\/v2\/pages\/4157\/revisions"}],"predecessor-version":[{"id":10935,"href":"https:\/\/www.operationalgroup.com\/de\/wp-json\/wp\/v2\/pages\/4157\/revisions\/10935"}],"up":[{"embeddable":true,"href":"https:\/\/www.operationalgroup.com\/de\/wp-json\/wp\/v2\/pages\/6225"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.operationalgroup.com\/de\/wp-json\/wp\/v2\/media\/3683"}],"wp:attachment":[{"href":"https:\/\/www.operationalgroup.com\/de\/wp-json\/wp\/v2\/media?parent=4157"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}